A 9-inch sterile PVC glove for tasks that need chemical resistance and a clean film rather than latex tactile response.

Selection note

Sterile PVC, 9 inch. PVC is the choice where latex sensitivity or chemical compatibility rules latex out, and it tolerates alcohols and dilute acids better than nitrile in short contact. The fit is looser; size down if the operator needs dexterity.

Construction

PVC gives a smooth, low-particle film that resists dilute acids and alcohols better than latex. The 9-inch length covers the wrist without bunching under a coverall cuff.

Where it is used

  • Aseptic handling of non-hazardous components
  • Chemical transfer in sterile support areas
  • Cleaning and disinfection tasks

On the line

PVC has less stretch than latex, so size by the palm rather than by habit. If the glove bridges the palm, the fingers will not reach the end of the glove and the tip will balloon.

Release check

Release check: seal strength and integrity, bioburden and sterility assurance level, indicator result and the barrier stack against the drawing. Sterility is released on the certificate for the lot; the carton label is only the summary.

Handling notes

PVC has less tactile feedback than latex. Where feel matters more than chemical resistance, specify the SS2006W latex glove.